Fantech dryer booster fan installation
You as the user, however, have the responsibility for verifying conformance with local codes and standards and ensuring a safe installation. It is the customer's responsibility to hire and retain suitable engineering and architectural professionals as required. Get expert advice from one of our HVAC engineers.
We're here Mon-Fri 8ampm Pacific. Starting a booster fan with a current switch. Quiet Kitchen Ventilation. Selecting correct fan for a bathroom. Using an in-line FR series fan. Ventilating multiple bathrooms with 1 fan. Dryer Booster Fans Residential. Wiring: 1 fan and 2 FD 60EM timers. Wiring: 1 fan serving 2 baths with 1 switch per bath. Wiring: Generic V coil relays.
There are no restrictions on its use with gas or electric dryers. Asked on by Valerie 2 Q: Can this booster fan be used with flexible venting? A: Yes it can. Flexible venting is discouraged for dryers due to the possibility of lint buildup.
The only restriction Fantech states is that the exhaust air temp from the dryer has to be less than F which is normally the case. Is it within code to have this Fan in the vent line. It is located in the last 15 feet of straight vent line, no more elbows.
Asked on by G 5 Q: Our house has a long run for two bath exhausts. Can I use a in-line dryer booster fan with pressure switch to help exhaust those bathrooms?
A: We would not recommend it. The Fantech dryer booster pressure switches are calibrated for a single 4 inch duct with the typical dryer airflow. You might not get consistent activation with any other installation. A: We stopped putting it together as a kit.
Fantech stopped as well. You can add the 2 items to your basket to get the same items. A: Indeed it does Asked on by Randy B 8 Q: Do you carry a dryer exhaust fan for a outside wall mount? Asked on by earl 9 Q: How close can these be mounted to the dryer? A: They need to be 15 feet away if you can, or as close as 5 feet with a lint trap installed. Asked on by Rob 10 Q: If you have to clean our the fan, do you have to remove the whole unit?
A: Yes, the fan must be removed to gain access to the interior of the unit. Asked on by Rick 11 Q: Can these be mounted on a vertical duct only? A: They can be mounted in any position so long as the pressure switch is in the correct orientation. Check the manual for current recommendations. A: Fantech recommends the use of a lint trap if the fan will be closer than 15 feet from the dryer. At that point the lint should be dry enough to pass through the fan.
Asked on by JC 13 Q: Whats better, the metal or plastic casing boosters? A: The metal case has a better seal, but the integrated nature of the plastic one makes installation a snap.
It will give an extra kick to the warm and moist air to escape the duct. Learn more. Airborne lint from your home's dryer may accumulate in the exhaust duct and cause some clogging issues. The secondary lint trap installed between the dryer and exhaust dryer ventilator filters the air catches the lint and protects the exhaust fan and the ductwork.